Does the distribution room need a gas fire extinguishing system?

编辑: 念海消防 来源: 念海消防 发布日期: 2019.07.20浏览次数: Author: Xiao Bian read sea edit: read sea Fire Source: read sea Fire Release date: 2019.07.20 Views:
Message summary:
The stability and safety of the power distribution room is related to the electricity consumption of the entire building. So, does the power distribution room need to be installed with a gas fire extinguishing system? Are there any relevant provisions in the fire protection code for the fire extinguishing design of the distribution room?

Does the distribution room need a gas fire extinguishing system? The stability and safety of the power distribution room is related to the electricity consumption of the entire building. Are there any relevant provisions in the fire protection code for the fire extinguishing design of the power distribution room, what kind of fire extinguisher or fire extinguishing system needs to be installed in the power distribution room, and is it necessary to install a gas fire extinguishing system? Nianhai Fire Fighting will explain it in detail for you.

The power distribution room is simply a room that distributes electrical energy. It mainly distributes electrical energy to users. It is equipped with switches, transformers, capacitors, and related protective measurement devices. Many buildings require separate power distribution rooms, such as large buildings such as residential quarters, hospitals, office buildings, and stations. Especially in summer, the power consumption increases sharply, the equipment cools down slowly, and the operation of the power supply system is particularly important. Among them, the safety of the power distribution room is even more important.

配电房气体灭火系统

Electrical equipment such as power distribution cabinets, power distribution boxes, and incoming cabinets are stored in the power distribution room. Once a fire occurs, it will affect the operation of the entire power supply and distribution system, causing economic losses, and even serious life-threatening situations. The fire classification of the power distribution room can be found in the "Classification of Building Fire Extinguisher Configuration Design Code" GB50140, which belongs to the category E fire: fires of charged objects must be extinguished with fire extinguishers that can meet the requirements of electrical insulation performance.

According to the "Code for Design and Design of Building Fire Extinguishers" GB 50140-2005:

4.2 Type selection of fire extinguisher

4.2.1E fire place should choose ammonium phosphate dry powder fire extinguisher, sodium bicarbonate dry powder fire extinguisher, halo fire extinguisher or carbon dioxide fire extinguisher, but the carbon dioxide fire extinguisher equipped with metal horn spray can not be selected.

The residues of dry powder fire extinguishers have a certain fouling effect on electrical equipment, and halogenated fire extinguishers have been banned in China according to the Montreal Convention agreement. Therefore, the best choice for fire extinguishers in distribution rooms is portable carbon dioxide fire extinguishers, portable heptafluoropropane fire extinguishers and other clean gases Fire extinguishers are used as auxiliary fires. At the same time, the fire extinguisher in the power distribution room should be located in a location that is obvious and easy to access, and it must not affect safe evacuation.

The portable gas fire extinguisher in the power distribution room only serves as a supplementary function. In addition, the power distribution room needs to be equipped with an automatic fire extinguishing system. Obviously, the sprinkler fire extinguishing system is not suitable for the particularity of electrical equipment fires in power distribution rooms and power distribution rooms. Does the distribution room need a gas fire extinguishing system?

According to the GB50370 "Code for Design of Gas Fire Extinguishing Systems", typical application places or objects of gas fire extinguishing systems are as follows:

3.2.1 The gas fire extinguishing system is suitable for the following fires:

1 electrical fire;

2 solid surface fire;

3 liquid fire;

4 Gas fire that can cut off the gas source before extinguishing the fire.

气体灭火系统

"Fire Code for Architectural Design" GB50016 We know that power distribution rooms and power distribution rooms are special important equipment rooms. It is stipulated in the code that special important equipment rooms such as power distribution rooms should be equipped with automatic fire extinguishing systems, and gas fire extinguishing systems should be adopted.

配电房气体灭火系统

It can be understood from the above that it is necessary to equip the distribution room with a gas fire extinguishing system, and it also meets the national fire protection regulations. As to which gas distribution system to choose, it needs to be considered from multiple levels.

Nianhai Firefighting works on hundreds of gas fire extinguishing systems in power distribution rooms every year. No matter from the design plan or construction experience, Nianhai Firefighting is already mature in the gas extinguishing system of power distribution rooms, and can be more careful Designing a Reasonable Solution for You! 免费咨询 在线客服或请拨打0512-67951790。 For details, please consult online customer service for free or call 0512-67951790.

Nianhai Fire Fighting is a professional gas fire extinguishing system manufacturer. At present, the more mature solutions are sevoflurane gas fire extinguishing system, carbon dioxide fire extinguishing system, IG541 fire extinguishing system, ultra-fine dry powder fire extinguishing system, fire detection fire extinguishing system, etc. Since the establishment of the company, it has served 1000+ enterprises, and has established a set of standardized and process-oriented systems for the distribution room gas fire extinguishing system solutions. Nianhai Fire Services has always served customers with a "renovation attitude for its own home". Choose Nianhai Fire to make you feel more at ease!

念海消防 

[Original statement: This article is an original article by Suzhou Nianhai Fire Fighting Technology Co., Ltd., please indicate the source and link for reprint, link address: kaakr.com]

Recommended information
中国联通消防气瓶检测

Nianhai Firefighting and China Unicom are connected because of fire gas cylinder detection

Fire gas fire extinguishing systems (commonly sevoflurane, IG541 and high pressure carbon dioxide fire extinguishing systems) are inspected every 3 years and nitrogen cylinders are inspected every 5 years. Fire cylinder inspection and filling project.
2019-06-03
老挝国家电网配电房灭火系统项目案例

Laos National Power Grid Fire Extinguishing System Project Case

Nianhai Fire Fighting Co., Ltd. designed a fire extinguishing system for the distribution room based on the customer's particularity. It is equipped with a cabinet-type heptafluoropropane fire extinguishing system. Adhering to the "customer-centric" concept during the construction process, we have solved the problems for customers and successfully completed the fire-extinguishing system project of the power distribution room.
2019-04-14
晋西集团江阳公司机房灭火系统案例

Computer room fire extinguishing system case of Jiangxi Company of Jinxi Group

The computer room fire extinguishing system has the advantages of high fire extinguishing efficiency, no pollution to equipment, good electrical insulation, and rapid fire extinguishing. The computer room fire extinguishing system configured for Jinxi Group Jiangyang Company is a cabinet-type heptafluoropropane fire extinguishing system.