Heptafluoropropane cylinder testing period-[Nianhai Fire Fighting]

编辑: 念海消防 来源: 念海消防 发布日期: 2019.11.12浏览次数: Author: Xiao Bian read sea edit: read sea Fire Source: read sea Fire Release date: 2019.11.12 Views:
Message summary:
Heptafluoropropane fire extinguishing system has high fire extinguishing efficiency, stable structure, and wide application range. Does heptafluoropropane cylinder need to be tested? How long is the testing period for sevoflurane cylinders?

Heptafluoropropane fire extinguishing system has high fire extinguishing efficiency and stable structure, and has been widely used in various computer rooms, power distribution rooms, archives, industrial equipment and other financial institutions, government agencies' key protection areas. Heptafluoropropane fire extinguishing agent has good stability under the conditions of suitable ambient temperature and good steel cylinder sealing, so the life span of heptafluoropropane fire extinguishing agent is relatively long. But how long is the testing period for sevoflurane cylinders ?

七氟丙烷钢瓶检测

How long is the testing period for sevoflurane cylinders?

According to the "Cylinder Safety Technical Supervision Regulations", the fire cylinders shall be inspected regularly.

The rules are as follows:

7.4.1 Inspection cycle of various types of gas cylinders

The inspection cycle of gas cylinders shall not exceed the provisions of this article.

Article 7.4.1.1 stipulates that seamless steel gas cylinders, steel welded gas cylinders, and aluminum alloy seamless gas cylinders:

(1) Cylinders containing nitrogen, sulfur hexafluoride, inert gases, and non-corrosive high-purity gases with a purity of 99.999% or more are inspected every 5 years;

(2) Cylinders, diving cylinders, and cylinders that often come into contact with seawater, which contain gases that have a high corrosive effect on the body material, shall be inspected every 2 years;

(3) Cylinders containing other gases shall be inspected every 3 years.

According to the above regulations, sevoflurane cylinders need to be inspected every three years.

七氟丙烷钢瓶检测

Necessity of sevoflurane cylinder testing

Fire-fighting gas cylinders include sevofluropropane cylinders, high-pressure carbon dioxide cylinders, and IG541 mixed gas cylinders. After being used for a long time, the cylinder body will be thinned due to external pollution, and cracks will occur due to moisture or other impurities in the cylinder. In case of high heat, the internal pressure of the container increases. If the sevoflurane cylinder is not tested in time, there will be danger of cracking and explosion, there will be major safety hazards, and it can endanger surrounding people in serious cases, resulting in personal injury and death, and relevant personnel will also bear corresponding legal responsibilities.

七氟丙烷钢瓶检测

Fire tank inspection and filling will cause more or less accidents if it is not handled properly or pays attention to it. Professional fire cylinder inspection units are required for inspection and filling. Nianhai Fire Protection provides professional fire cylinder testing and filling services, including sevoflurane cylinder testing and filling, carbon dioxide cylinder testing and filling, and IG541 mixed gas cylinder testing and filling services. He has cooperated with many enterprises and institutions, such as Tongcheng Tourism Building, Suzhou Cultural Expo Center, China Unicom Suzhou Branch, JD Cloud Data, Huaibei Datang Power Plant, etc., and has its own engineering and technical personnel, special car transportation, and holding a certificate. High professionalism, good service, trusted by customers!

七氟丙烷钢瓶检测

七氟丙烷钢瓶检测

Since the establishment of the company, it has served 1000+ enterprises. A set of standardized and process-based systems have been established in the inspection and filling service of fire cylinders. 具体可咨询念海工程师热线:0512-67951790。 Choosing Nianhai Fire Fighting will give you peace of mind and peace of mind. For details, please consult Nianhai Engineer Hotline: 0512-67951790.

念海消防 

载请注明出处与链接】 [Responsible editor: Suzhou Nianhai Fire Protection Technology Co., Ltd. All rights reserved: http://kaakr.com Reprinted , please indicate the source and link]

【related suggestion】
Recommended information
中国联通消防气瓶检测

Nianhai Firefighting and China Unicom are connected because of fire gas cylinder detection

Fire gas fire extinguishing systems (commonly sevoflurane, IG541 and high pressure carbon dioxide fire extinguishing systems) are inspected every 3 years and nitrogen cylinders are inspected every 5 years. Fire cylinder inspection and filling project.
2019-06-03
老挝国家电网配电房灭火系统项目案例

Laos National Power Grid Fire Extinguishing System Project Case

Nianhai Fire Fighting Co., Ltd. designed a fire extinguishing system for the distribution room based on the customer's particularity. It is equipped with a cabinet-type heptafluoropropane fire extinguishing system. Adhering to the "customer-centric" concept during the construction process, we have solved the problems for customers and successfully completed the fire-extinguishing system project of the power distribution room.
2019-04-14
晋西集团江阳公司机房灭火系统案例

Computer room fire extinguishing system case of Jiangxi Company of Jinxi Group

The computer room fire extinguishing system has the advantages of high fire extinguishing efficiency, no pollution to equipment, good electrical insulation, and rapid fire extinguishing. The computer room fire extinguishing system configured for Jinxi Group Jiangyang Company is a cabinet-type heptafluoropropane fire extinguishing system.
2019-04-13

support hotline

0512-67951790

Nianhai Fire Fighting

Focus on providing fire protection solutions in key protective areas 0512-67951790