159彩票

念海消防

管网式七氟丙烷灭火系统

support hotline

0512-67951790
  • 管网七氟丙烷灭火系统
Pipe network heptafluoropropane fire extinguishing system

Features: 1. Combined allocation, can protect 2-8 protection zones at the same time.
2. The gas cylinders are fixedly installed in specific gas cylinders and do not take up space in the protective area.
3. Pipe network heptafluoropropane fire extinguishing system nozzles are evenly distributed, more evenly discharged, which is conducive to fire extinguishing.

Application Scenario: Pipe network sevoflurane fire extinguishing system can be used to protect places with frequent people and high-precision electronic instruments, communication equipment and other high-value property and important places. It is suitable for fighting A, B, C and E electrical fires, such as Communication room, high and low voltage distribution room, archive room, energy storage container, industrial cleaning equipment, dangerous goods warehouse and other flammable and explosive places.

National Hotline

0512-67951790

系统简介

introduction

The pipe network heptafluoropropane fire extinguishing system is a fully submerged fire extinguishing system. According to the requirements of the specification and the site conditions, it can be divided into two types of unit independent systems and combined distribution systems. There are four control modes: automatic, manual, mechanical emergency manual and emergency start / stop.

Pipe network heptafluoropropane fire extinguishing system consists of pipe network heptafluoropropane fire extinguishing device, pipe network, gas fire extinguishing controller, fire detector, sound and light alarm, gas release indicator, emergency start and stop button, peripheral power supply and so on.

Pipe network heptafluoropropane fire extinguishing system

管网七氟丙烷灭火系统原理图

技术参数

Technical Parameters

Pipe network heptafluoropropane fire extinguishing system
Storage pressure of fire extinguisher bottle group (20 ℃) 4.2MPa 5.6MPa
Volume of extinguishing agent storage bottle (L) 70, 90, 120, 150 70,90,120
Working pressure (50 ℃) 5.3 MPa 8.0 MPa
Minimum working pressure (0 ℃) 3.6 MPa 4.6 MPa
Filling density of fire extinguishing agent (Kg / m³) 950 1080
Fire extinguishing agent name Heptafluoropropane (HFC-227ea)
Working temperature range (℃) 0 ~ + 50
Fire extinguishing agent spray time (S) ≤10
Drive gas cylinder set storage pressure 6.0 MPa
Power on DC24V, 1.6A
Fire fighting form Fully submerged
Fire concentration Determined according to the nature of the combustibles in the protected area
Start way Automatic; electrical manual; mechanical emergency manual operation


系统应用场景

System application scenario

管网七氟丙烷灭火系统应用场景

独特优势

Unique advantages

Details highlight product quality

七氟丙烷气瓶

Heptafluoropropane gas cylinder

The wall thickness of the gas cylinder container used in the pipe network heptafluoropropane fire extinguishing system is about 2mm thicker than that of the same industry. The wall thickness and strength are high, and the risk of gas cylinder explosion is low. The service life is about 5 years longer than the gas cylinders in the same industry. low.

Pressure gauge

The airtightness of the valve head is good, the pressure of the pressure gauge is stable, and the pressure drop rate is controlled at 0.02%. There is no frequent pressure drop, and it is avoided to be fined because the pressure gauge has no pressure during the fire inspection.
压力表
七氟丙烷钢瓶固定框架

Bottle group fixed frame

The bottle frame fixed frame is made of square steel, and its structural strength is 3-5 times stronger than the angle steel used in the same industry. The pipe parts and components are all high-standard products that are resistant to high pressure.

Heptafluoropropane

Heptafluoropropane medicaments are never short of two pounds, 100% in line with the customer's order amount, to avoid legal liability caused by insufficient fire caused by the fire can not be effectively extinguished.
七氟丙烷药剂

解决方案 Obtain pipe network heptafluoropropane fire extinguishing system solution

0512-67951790

资质齐全

Complete qualifications

Complete qualifications to improve bid winning rate

Certifications

生产环境

Production Environment

Approach our factory and experience our intentions

安徽集友股份管网七氟丙烷灭火系统

苏州服务外包学院七氟丙烷气瓶检测充装

苏州同程大厦消防气瓶检测充装

联系念海

Contact Nianhai

Suzhou Nianhai Fire Fighting Technology Co., Ltd.

手机:139-5110-6386 微信:13951106386 邮箱:sznianhai@163.com 公司地址:苏州市姑苏区福运路198号 Service Hotline: 0512-67951790 Mobile: 139-5110-6386 WeChat: 13951106386 Email: sznianhai@163.com Company Address: No. 198, Fuyun Road, Gusu District, Suzhou City
"Simple, sincere and kind are our business cards!"
Hot product
气溶胶灭火装置

Aerosol fire extinguishing device

Aerosol fire extinguishing devices can be divided into K type and S type according to the type of extinguishing agent. According to the temperature of the nozzle of the fire extinguishing device, it can be divided into temperature-limiting type and non-temperature-limiting type. Used to extinguish electrical appliance fires, solid surface fires, and liquid fires.
柜式超细干粉灭火装置

Cabinet type superfine dry powder fire extinguishing device

[Characteristics of cabinet-type ultra-fine dry powder fire extinguishing device]: Beautiful appearance, simple structure, convenient and quick start. The cabinet type ultra-fine dry powder fire extinguishing device is linked with the fire detection and alarm system, which is suitable for both full submerged automatic fire extinguishing and large area local protection.
管网超细干粉自动灭火装置

Superfine dry powder automatic fire extinguishing device for pipe network

Ultra-fine dry powder pipe network automatic fire extinguishing device: The ultra-fine dry powder fire extinguishing agent in the fire extinguishing agent storage tank is driven by a high-pressure nitrogen cylinder group, and is transported through a pipe network to a nozzle set in the protection area to spray at high speed and extinguish the fire quickly. It is suitable for protecting large spaces from submerged fire extinguishing and local protection applications to extinguish large areas of fire.
气体灭火报警主机

Gas fire alarm host

System introduction: The gas fire extinguishing controller is mainly used for various fire extinguishing systems such as piped or non-piped heptafluoropropane, high pressure carbon dioxide, ig541, aerosol and fire extinguishing systems such as ultra-fine dry powder, which can be directly connected to smart smoke and temperature fire The detector can also be connected to a non-coded fire detector through a smart non-coded detector interface (relay module) to perform a fire alarm.

Nianhai Fire Fighting

Focus on providing fire protection solutions in key protective areas 0512-67951790