159彩票

念海消防

二氧化碳灭火系统

support hotline

0512-67951790
  • 高压二氧化碳灭火系统
High pressure carbon dioxide fire extinguishing system

[Features]: The high-pressure carbon dioxide fire extinguishing system is the earliest and most mature gas fire extinguishing system, which has the advantages of good fire extinguishing effect, no pollution to equipment, and good insulation performance.

[Application scenario]: High-pressure carbon dioxide fire extinguishing system is suitable for industrial construction projects such as aluminum cable, coating line, cement production line, steel industry, power plant, etc., and is also suitable for fighting B, C and electrical fires.

National Hotline

0512-67951790

系统简介

:高压二氧化碳灭火系统是目前气体灭火系统中灭火技术最成熟的固定式气体灭火系统,在工业发达的国家应用相当广泛,我国使用于70年代。 System introduction : The high-pressure carbon dioxide fire extinguishing system is the most mature fixed gas fire extinguishing system in the current fire extinguishing system. It is widely used in industrially developed countries. Our country used it in the 1970s. Carbon dioxide fire extinguishing agent is colorless, odorless, non-corrosive, non-residual, non-conductive, and low-toxic. It will not cause pollution and leave no trace on the object to be protected after fire extinguishing.

高压 二氧化碳全淹没灭火系统不得应用于经常有人停留的场所,不宜保护紧密仪器设备。 System features : The high-pressure carbon dioxide full-submerged fire extinguishing system should not be used in places where people often stay, and it should not be used to protect tight equipment.

:高压二氧化碳灭火装置、气体灭火控制器、火灾探测器、声光报警器、放气指示灯、紧急启停按钮、外设电源等组成完整的自动灭火系统。 System composition:: High-pressure carbon dioxide fire extinguishing device, gas fire extinguishing controller, fire detector, sound and light alarm, gas release indicator, emergency start and stop button, external power supply, etc. form a complete automatic fire extinguishing system.

二氧化碳2模糊

技术参数

Main technical parameters of high pressure carbon dioxide fire extinguishing device
model Design pressure of storage cylinder (Mpa) Storage cylinder working pressure (Mpa) Storage cylinder strength test pressure (Mpa) Airtight test pressure (Mpa) Overpressure test pressure (Mpa) Storage ambient temperature (℃) Storage cylinder nominal volume (L)
PZ-00 15 15 22.5 15 45 0-49 70
Maximum filling density of fire extinguishing agent (KG / L) Maximum charge of fire extinguishing agent (KG) Filling weight error of fire extinguishing agent (KG) Bottle assembly height (L) (mm) Bottle outer diameter (mm) Bottle connection thread specifications Empty bottle weight (KG)
0.6 42.63 0-0.63 1603 267 NPT1 ~ 78

注意事项

喷射灭火剂前,所有工作人员必须在延时时间内撤离火情现场;灭火完毕后,必须首先启动风机,待废气排出后,工作人员方可进入现场。 1. Before the high pressure carbon dioxide fire extinguishing system sprays the fire extinguishing agent, all workers must evacuate the fire scene within the delay time; after the fire extinguishing, the fan must be started first, and the workers can enter the scene after the exhaust gas is discharged.
2. The installation place of this device should meet the following requirements:
(1) The ambient temperature is 0 ~ 50 ℃, and keep dry and well ventilated.
(2) The air should not contain harmful substances that are corrosive to explosive, conductive dust and Egyptian corrosion parts, otherwise they must be protected and the system must not be subject to vibration and shock.
3. The personnel who install and debug the system should be familiar with the basic structure, working principle, performance and action procedures of the system, as well as the basic structure and working status of each valve.
4. Keep gas cylinders away from heat sources. During transportation, it should be lightly loaded and unloaded, and collision, lying or upside-down is strictly prohibited.
5. Replacement of new safety diaphragms must be provided by our company, and non-tested diaphragm replacements shall not be used at will.
6. During the disassembly process, avoid touching the surface and affecting the appearance.
7. Irrelevant personnel must not touch the components of this system to avoid accidents.

案例展示

二痒化碳应用案例

5大服务优势

科学量身出具方案专业设计团队

Scientifically tailored solutions professional design team
10 years of gas fire extinguishing system design experience

品牌厂家直销品质有保障

The quality of the brand and factory direct sales guarantees that the gas fire extinguishing system is fully functional and accurate and reliable, and it does not leak during long-term storage.

售后

Improve after-sale system Support failures during the whole process, immediate response after 24 hours of after-sale

检测充装

Fire gas cylinder testing and filling service Fully qualified gas pressure vessel testing and filling service related qualification certification unit

专业施工团队

Professional construction team Cooperate on-site installation and commissioning without any worries, comply with the detection mechanism throughout the process, accelerate the fire inspection and pass the accident-free construction standards

Hot product
管网七氟丙烷灭火系统

Pipe network heptafluoropropane fire extinguishing system

Features: 1. Combined allocation, can protect 2-8 protected areas at the same time. 2. The gas cylinders are fixedly installed in specific gas cylinders and do not take up space in the protective area. 3. Pipe network heptafluoropropane fire extinguishing system nozzles are evenly distributed, more evenly discharged, which is conducive to fire extinguishing. Application Scenario: Pipe network sevoflurane fire extinguishing system can be used to protect places with frequent people and high-precision electronic instruments, communication equipment and other high-value property and important places. It is suitable for fighting A, B, C and E electrical fires, such as Communication room, high and low voltage distribution room, archive room, energy storage container, industrial cleaning equipment, dangerous goods warehouse and other flammable and explosive places.
气溶胶灭火装置

Aerosol fire extinguishing device

Aerosol fire extinguishing devices can be divided into K type and S type according to the type of extinguishing agent. According to the temperature of the nozzle of the fire extinguishing device, it can be divided into temperature-limiting type and non-temperature-limiting type. Used to extinguish electrical appliance fires, solid surface fires, and liquid fires.
柜式超细干粉灭火装置

Cabinet type superfine dry powder fire extinguishing device

[Characteristics of cabinet-type ultra-fine dry powder fire extinguishing device]: Beautiful appearance, simple structure, convenient and quick start. The cabinet type ultra-fine dry powder fire extinguishing device is linked with the fire detection and alarm system, which is suitable for both full submerged automatic fire extinguishing and large area local protection.
气体灭火报警主机

Gas fire alarm host

System introduction: The gas fire extinguishing controller is mainly used for various fire extinguishing systems such as piped or non-piped heptafluoropropane, high pressure carbon dioxide, ig541, aerosol and fire extinguishing systems such as ultra-fine dry powder, which can be directly connected to smart smoke and temperature fires. The detector can also be connected to a non-coded fire detector through a smart non-coded detector interface (relay module) to perform a fire alarm.

Nianhai Fire Fighting

Focus on providing fire protection solutions in key protective areas 0512-67951790