Fire extinguishing system in electric machine room

电力机房灭火系统

在信息化程度越来越高的今天,担当信息处理与交换重任的机房是整个信息网络工程的数据传输中心、数据处理中心和数据交换中心。 Computer room fire extinguishing system requirements: Today, with the increasing degree of informationization, the computer room responsible for information processing and exchange is the data transmission center, data processing center and data exchange center of the entire information network project. In order to ensure that the equipment room and staff have a safe working environment, the fire protection system of the machine room is particularly important. Article 8.3.9 of the Code for Fire Protection in Architectural Design stipulates that automatic fire extinguishing systems should be installed in important equipment rooms such as the machine room, and gas fire extinguishing should be used. system.

七氟丙烷气体灭火系统 、超细干粉灭火系统 Applicable fire extinguishing system: Heptafluoropropane gas fire extinguishing system , ultra-fine dry powder fire extinguishing system

-Fire fighting system features-

  • Heptafluoropropane gas fire extinguishing system features

Heptafluoropropane gas fire extinguishing system can extinguish Class A, B, C and electrical fires. It can be used to protect people's places. The heptafluoropropane fire extinguishing agent is non-conductive and low-toxic. It is completely volatilized at normal temperature and pressure. Causes secondary damage to electrical equipment and precision instruments, and should be suitable for fire extinguishing in computer rooms.

  • Superfine dry powder fire fighting features

灭火系统可以扑救A、B、C类火灾和带电设备火灾,并且超细干粉灭火剂不含活泼金属,不会吸收空气中的水分,因而不会形成具有导电性和腐蚀性的电解质液膜,从而避免了对电器设备造成的损坏,灭火后残留物易清理, 适合用于机房灭火。 The ultra-fine dry powder fire extinguishing system can extinguish Class A, B, and C fires and fires of charged equipment. The ultra-fine dry powder fire extinguishing agent does not contain active metals, does not absorb moisture in the air, and therefore does not form conductive and corrosive electrolytes. Liquid film to avoid damage to electrical equipment. Residues are easy to clean up after fire extinguishing, which is suitable for fire extinguishing in computer rooms.

疑问 What have we done for our customers?

1. Go to the survey site in time, communicate with customers and design plans.
2. Supply, dismantle old equipment, install new equipment, and simulate discharge experiments.
培训和现场模拟操作,并及时解决了用户在使用过程中出现的问题。 3. Developed a special plan and training manual, carried out multiple trainings and field simulation operations of the computer room fire extinguishing system for the users, and solved the problems in the use of the users in a timely manner.

疑问 What points can't peers do?

1. Investigate the site to determine whether the project meets the construction conditions; determine the remaining parts of the original system, the parts to be transformed; determine the type of the new system, and give a design plan and a preliminary construction plan.
2. Strict quality control during the construction process, pay attention to details, and make sure that the inspection and acceptance on the day of construction is passed.

苏州阿特斯电力

Suzhou Atlas Solar Power Technology is located in Suzhou, Jiangsu, and was established in June 2006 by Canadian Solar Inc. (CSI).
The protection area is a high-voltage power distribution cabinet. Is a professional company integrating solar photovoltaic module manufacturing and providing solar energy application product research and development, design, manufacturing and sales to global customers.
Fire protection products: Cabinet-type heptafluoropropane fire extinguishing device.

- Business advantage-

量身定制解决方案

Scientifically tailored solutions tailored

供应

Quality Assurance

团队

Professional construction team has no worries

售后

Improve after-sales system support

服务

Complete testing and filling service qualifications